Espressif Systems /ESP32 /TIMG0 /T0CONFIG

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as T0CONFIG

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (ALARM_EN)ALARM_EN 0 (LEVEL_INT_EN)LEVEL_INT_EN 0 (EDGE_INT_EN)EDGE_INT_EN 0DIVIDER0 (AUTORELOAD)AUTORELOAD 0 (INCREASE)INCREASE 0 (EN)EN

Fields

ALARM_EN

When set alarm is enabled

LEVEL_INT_EN

When set level type interrupt will be generated during alarm

EDGE_INT_EN

When set edge type interrupt will be generated during alarm

DIVIDER

Timer 0 clock (T0_clk) prescale value.

AUTORELOAD

When set timer 0 auto-reload at alarming is enabled

INCREASE

When set timer 0 time-base counter increment. When cleared timer 0 time-base counter decrement.

EN

When set timer 0 time-base counter is enabled

Links

() ()